Protocol Analysis
R&S
®
RTO
314User Manual 1316.0827.02 ─ 06
Error conditions
Triggers on one or more errors in the frame.
Trigger type: "Error conditions"
"FSS"
Error in a Frame Start Sequence. FSS follows the Transmission Start
Sequence TSS at the beginning of each frame.
"BSS"
Error in a Byte Start Sequence. The BSS is transmitted before each
byte.
"FES"
Error in Frame End Sequence. FES indicates the end of each frame.
"Header CRC"
Error in a cyclic redundancy check code of the header data which cov-
ers mainly frame ID and payload length.
"Payload CRC"
Error in a cyclic redundancy check code of the complete frame.
SCPI command:
TRIGger<m>:FLXRay:FSSerror on page 731
TRIGger<m>:FLXRay:BSSerror on page 730
TRIGger<m>:FLXRay:FESerror on page 731
TRIGger<m>:FLXRay:HCRCerror on page 731
TRIGger<m>:FLXRay:PCRCerror on page 731
10.7.1.3 FlexRay Decode Results
To display the decoded signal below the waveforms, enable "Decode" on the "Configu-
ration" tab.
Additionally, you can display the binary signal and the detailed decoding results using
the corresponding settings on the "Display" tab, see chapter 10.1.2, "Dis-
play", on page 251.