Parameters:
<THResholds> Differential or absolute voltage level, depending on the source
type. See BUS<m>:FLXRay:SRCType on page 717.
BUS<m>:FLXRay:THENable <ThresholdEnable>
Sets the threshold for the enable line if the source type is LOGic.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<ThresholdEnable> Range: -12 to 12
Increment: 0.1
*RST: 2.65
Default unit: V
BUS<m>:FLXRay:THData <ThresholdData>
Sets the threshold for the data line if the source type is LOGic.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<ThresholdData> Range: -12 to 12
Increment: 0.1
*RST: 2.35
Default unit: V
BUS<m>:FLXRay:PRSingle <PresetSingleEnded>
Selects a default threshold voltage if BUS<m>:FLXRay:SRCType is set to SINGle.