Digi-Frame DF-1044r Manual de usuario Pagina 460

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 829
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 459
Remote Control
R&S
®
RTO
444User Manual 1316.0827.02 ─ 06
Parameters:
<ProbeGainModeManual>Range: 100E-6 to 10
Increment: 0.01
*RST: 0.1
Default unit: V/V
PROBe<m>:SETup:MEASurement <ProbeMeterMeas>
Selects the input voltage that is measured by the differential active probe.
See also: "Differential active probes" on page 22.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ProbeMeterMeas> DIFFerential | COMMonmode
DIFFerential
Measures the voltage between the positive and negative signal
sockets.
COMMonmode
Measures the mean voltage between the signal sockets and the
ground socket.
*RST: NONE
CHANnel<m>:EATScale <ExtAttScale>
Sets the attenuation scale for an external divider.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ExtAttScale> LIN | LOG
*RST: LIN
CHANnel<m>:EATTenuation <ExtAtt>
Sets the attenuation of an external voltage divider.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ExtAtt> Range: 1E-3 to 1000
Increment: 0.01
*RST: 1
Default unit: The unit depends on the selected scale.
Command Reference
Vista de pagina 459
1 2 ... 455 456 457 458 459 460 461 462 463 464 465 ... 828 829

Comentarios a estos manuales

Sin comentarios