Digi-Frame DF-1044r Manual de usuario Pagina 746

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 829
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 745
Remote Control
R&S
®
RTO
730User Manual 1316.0827.02 ─ 06
TRIGger<m>:FLXRay:DMIN <DataPattern>
Specifies a data pattern, or sets the the start value of a data pattern range.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPattern>
Numeric or string pattern, see chapter 16.2.2.6, "Bit Pattern
Parameter", on page 421. The string parameter accepts the bit
value X (don't care).
TRIGger<m>:
FLXRay:DMAX <DataPatternTo>
Sets the the end value of an data range if the operator TRIGger<m>:FLXRay:
DCONdition is set to INRange or OORange.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPatternTo>
Numeric or string pattern, see chapter 16.2.2.6, "Bit Pattern
Parameter", on page 421. The string parameter accepts the bit
value X (don't care).
TRIGger<m>:FLXRay:SYMBol <Symbol>
Triggers on a symbol or on a wakeup pattern.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<Symbol> CASMts | WAKeup
CASMts
Collision Avoidance Symbol / Media access Test Symbol. These
symbols are identical and can be sent in the optional symbol win-
dow at the end of a communication cycle. They are used to avoid
collisions during the system start.
WAKeup
The wakeup pattern is sent to activate the nodes of the system.
*RST: CASMts
TRIGger<m>:FLXRay:BSSerror <BSSError>
Triggers on error in SyteStart Sequence. The BSS is transmitted before each byte.
Command Reference
Vista de pagina 745
1 2 ... 741 742 743 744 745 746 747 748 749 750 751 ... 828 829

Comentarios a estos manuales

Sin comentarios