Digi-Frame DF-1044r Manual de usuario Pagina 611

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 829
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 610
Remote Control
R&S
®
RTO
595User Manual 1316.0827.02 ─ 06
Parameters:
<HorizontalMode> ORIGinal | COUPled
ORIGinal
Horizontal scaling and reference point of the source waveform are
used.
COUPled
The current horizontal settings of the diagram are used.
*RST: ORIGinal
REFCurve<m>:
RESCale:HORizontal:STATe <State>
Enables and disables the horizontal stretching.
Stretching changes the display of the waveform independent of the horizontal settings of
the source waveform and of the horizontal diagram settings.
Suffix:
<m>
.
1..4
Reference waveform
Parameters:
<State> ON | OFF
*RST: OFF
REFCurve<m>:RESCale:HORizontal:FACTor <ScaleFactor>
A factor greater than 1 stretches the waveform horizontally, a factor lower than 1 com-
presses the curve.
Suffix:
<m>
.
1..4
Reference waveform
Parameters:
<ScaleFactor> Range: 1E-6 to 1E+6
Increment: 0.1
*RST: 1
REFCurve<m>:RESCale:HORizontal:OFFSet <Offset>
Moves the waveform horizontally. Positive values shift the waveform to the right, negative
values shift it to the left.
Suffix:
<m>
.
1..4
Reference waveform
Command Reference
Vista de pagina 610
1 2 ... 606 607 608 609 610 611 612 613 614 615 616 ... 828 829

Comentarios a estos manuales

Sin comentarios