MEASurement<m>:SPECtrum:CPOWer:BANDwidth <ChPowBandwidth>
Defines the bandwidth over which the channel power is calculated.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<ChPowBandwidth> Range: 0 to 4E+9
Increment: 1
*RST: 0
Default unit: Hz
MEASurement<m>:SPECtrum:OBANdwidth <OccupiedBW>
Defines the percentage of the total power used to determine the occupied bandwidth.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<OccupiedBW> Range: 0.1 to 99.9
Increment: 1
*RST: 20
Default unit: %
MEASurement<m>:SPECtrum:CPOWer:CFRequency <CenterFreq>
Defines the center frequency from which the channel power is calculated over the speci-
fied bandwidth.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<CenterFreq> Range: 0 to 6E+9
Increment: 1
*RST: 0
Default unit: Hz
MEASurement<m>:SPECtrum:NDBDown <NDbDown>
Defines the threshold until which the samples to the left and right of the peak value are
analyzed in order to determine the "N dB down bandwidth".
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.